DPSGWMOCS1 Floor Stand Design DPSGWMOCS1 SCADA
Floor Stand Design SCADA
DPSGWMOCS1 2 Workplaces
14 Basic Experiments For 2 Team Members
Request for quotation

Lifetime Support

2-year warranty & further tech back up

Misuse excused

Protection from short circuits, negligence & damage

Didactic guides

Step-by-step tutorials included for your quick start

Customization

Add extra modules needed or remove unwanted ones

Steady-state modes of elements of electric distribution network (Full-scale simulation of steady-state mode of single-phase transformer; Full-scale simulation of steady-state mode of one phase of network; Readout of static characteristics of the power for static load)

Steady-state modes of the power distribution network (Full-scale simulation of steady-state mode of one phase of network with single-sided supply / two-sided supply)

Voltage regulation in electric distribution network (Counter voltage regulation; Voltage regulation by cross compensation of reactive power with capacitor banks)

Optimization of the local electricity distribution network modes (Detecting active power losses in local power distribution network composed by loop scheme; Evaluation of effect of difference in the voltages at busbars of power centers on loss of active power in local electric distribution network, composed by loop scheme, when it operates in closed mode; Evaluation of effect of rupture of local electric distribution network, composed by loop scheme, on loss of active power; Finding point of normal (optimal) rupture in local electric distribution network, composed by loop scheme, according to the criterion of minimum active power losses; Operation of local electric distribution network, made by loop scheme, in mode of automatic point selection of normal (optimal) rupture according to the criterion of minimum active power losses)

Optimization of the regional electricity distribution network modes (Measurement and calculation of closed (circular) regional electric distribution network mode parameters; Finding optimal power of the compensating capacitors in closed (circular) regional electric distribution network according to the criterion of minimum active power losses)
Single-Phase Power Supply;
Electric Transmission Line Model;
Capacitive Load;
Single-PhaseTransformer;
Transformer Substation and Load Model;
Electric Network Parameters Measurement Tool;
Laboratory Table With 3-Level Frame, Container and Rack;
Accessories Kit;
SCADA Software CD-ROM;
Uninterruptible Power Supply;
Notebook
Width х Depth х Height: 910 х 850 х 1900 mm
Weight: ~110 kg
Power supply: 220 V / 50 Hz
Appliance Class: I
Basic Experiments Guide